<< Previous
SITE PERFORMANCE SUMMARY
 
   
 
   
 
 



Site: Pearl Harbor, HI

   
Total
Unit # 252
Start Date  
--
2/26/2004
Thru Date
--
8/31/2005
Hours of Operation
Hours
4462
4462
kWh Output
kWh
10843.1
10843.1
Input Fuel
MMBTU
158.1
158.1
Electric Efficiency
%
23.41%
23.41%
Availability
%
99.98%
99.98%
Capacity Factor
%
48.69%
48.69%

 

Unit#1 (System Number#SU01B000000252)

Date
Oper. Hours
Total kWh
Avg. kW
Capacity Factor
Availability
Input Fuel (MMBTU)
Electric Eff.
08/04
0.0
0.0
0.00
0.00%
0%
0.00
0.00%
09/04
0.0
0.0
0.00
0.00%
0%
0.00
0.00%
10/04
0.0
0.0
0.00
0.00%
0%
0.00
0.00%
11/04
0.0
0.0
0.00
0.00%
0%
0.00
0.00%
12/04
0.0
0.0
0.00
0.00%
0%
0.00
0.00%
01/05
0.0
0.0
0.00
0.00%
0%
0.00
0.00%
02/05
48
118.63
2.47
49.43%
100%
1.74
23.2%
03/05
744
1769.24
2.38
47.56%
100%
26.03
23.1%
04/05
720
1781.78
2.47
49.49%
100%
25.25
24.0%
05/05
743
1846.39
2.48
49.63%
99.8%
25.63
24.5%
06/05
720
1721.6
2.39
47.82%
100%
25.5
23.08%
07/05
744
1785.7
2.40
48.00%
100%
26.4
23.04%
08/05
743
1819.7
2.45
48.92%
99.97%
27.3
22.74%
               

 

Average kW = kWh ÷ Operating Hours
Availability = Operating Hours ÷ Hours in Period
Capacity Factor = Total kW Hours ÷ [Total Period Hours * Fuel Cell Rated kW]
Electrical Efficiency = [kWh x 3413 Btu/kWh] ÷ [Input Fuel MMBTU x 1 million Btu/MMBTU]

 

Back to top of page

©2004 Sandia National Laboratories | Privacy and Security | Contact Us

[Mail to:] Lisa Sena-Henderson
Last modified: June 26, 2005